A storage engineer must grant access of a Dell Unity XT provisioned NFS datastore to ESXi-1.dell.local. The NAS server used to create the datastore is configured for NFSv4 protocol with Kerberos NFS owner authentication.
Which permission level is required for the ESXi host?
A. Read/write
B. Read-only
C. Read/write, enable Root
A company has an ESXi host installed with FC HBAs that is connected to a Dell Unity XT storage array. A 500 GB LUN is provisioned to this host from the Unity array and is in production. The VMware administrator has configured a new vSwitch with the NICs on the server intended for iSCSI traffic. The storage administrator is asked to configure software iSCSI and provision a new 1 TB LUN from the storage array using iSCSI.
What is a consideration when satisfying this request?
A. Two iSCSI target interfaces must be configured with IP addresses from separate subnets.
B. Any single host should connect to any single array using one protocol only.
C. A connection must be established between the host iSCSI initiators and Unity iSCSI targets before provisioning the new LUN.
A storage administrator must configure replication from a production Dell Unity XT 680F to an offsite DR Dell Unity XT 480. Block resources must be replicated without data loss if the production site becomes unavailable. File resources can
be replicated with an acceptable amount of data difference on the destination.
What replication configuration meets the requirements?
A. Set Unisphere resource filtering to All.
B. Configure the replication connection mode to Both.
C. Set an RPO of 0 on the synchronous replication sessions.
D. Configure the replication interfaces on the 4-port mezzanine card.
An administrator has configured a Host Group to have access to a storage object.
What are two benefits of this configuration? (Choose two.)
A. Ensures that snapshots are applied to all LUNs in the group
B. Provides multiple hosts the same access to NFS Filesvstems
C. Provides multiple hosts access to the same VMFS Datastores
D. Ensures that block storage is replicated to the same hosts
E. Provides multiple hosts access to the same LUNs
Which I/O modules does the Unity 380/380F system support?
A. 12 Gb/s SAS 2-Port 100 GbE
B. 32 Gb/s Fibre Channel 10 GbE Base-T
C. 12 Gb/s SAS 10 GbE Base-T
D. 32 Gb/s Fibre Channel 2-Port 100 GbE
A deployment engineer has changed theSchedule Time Zoneunder the Settings menu. However, existing snapshots schedules continue to run at the previously configured time.
Why is this occurring?
A. Existing snapshot schedules cannot be updated to the same absolute time.
B. The Unity system time is not set correctly and must be updated under system settings.
C. Existing snapshot schedules are not updated to the same absolute time when the time zone is changed.
D. The Unity management server was not restarted before time zone changes took effect.
What is a characteristic of FAST VP?
A. Fast VP data relocation runs in the background at all times once it is enabled.
B. Fast VP optimizes data replacement by moving 1 GB slices between disk tiers.
C. Users can set the Fast VP data relocation rate.
D. Users can enable or disable FAST VP at the LUN level.
What is the result of enabling Data Reduction on a LUN in a consistency group containing three LUNs?
A. Any writes to the LUN will go through the Data Reduction logic.
B. Data Reduction and Advanced Deduplication will be enabled on all LUNs.
C. Data Reduction will be enabled on all LUNs is the consistency group.
D. All writes to all consistency group LUNs will go through the Data Reduction logic.
What is the maximum number of drives on a traditional RAID Group?
A. 64 drives
B. 16 drives
C. 8 drives
D. 32 drives
Which two actions are recommended according to best practices when connecting iSCSI host to a Dell Unity XT system? (Choose two.)
A. Manually register host on storage array.
B. Use standard NIC for iSCSI.
C. Interfaces should be on separate subnets.
D. Use private network for iSCSI interfaces.