What is provided by the serial port hardware interface for managing network devices?
A. scalability
B. ability to offload functions from the host
C. well-defined communications standards
D. caching and advanced functions
Which statements are true about active and passive cooling systems? (Select two)
A. A passive cooling system uses only heat sinks.
B. An active cooling system uses only heat sinks.
C. An active cooling system adds devices such as fans.
D. A passive cooling system adds devices such as fans.
Which statement is true about a JBOD?
A. It is configured as a RAID 0 by default.
B. It contains a minumum of one hot spare disk.
C. It offers no data redundancy or striping
D. It is connected to a minimum of two hosts by default.
A customer complains about server performance. Performance parameters show the following information:
Network Segment: % Network Utilization - 55%
Page/Sec - 7
% Processor Time - 55%
% Disk Time - 35%
A. disk
B. network
C. memory
D. processor
Which port type does a host server use when connected to an FC-SAN?
A. N_Port
B. E_Port
C. G_Port
D. F_Port
Which Network Operating System (NOS) filesystem allows you to set security on invididual files?
A. FAT32
B. FAT
C. NTFS
D. CDFS
Your customer's workstation has four 15K rpm SAS drives. The customer wants the best possible performance, and is not concerned about data loss. Which RAID level best meets this customer's needs?
A. RAID 0
B. RAID 1
C. RAID 5
D. RAID 6
If the GFS backup tape rotation plan, how often is the Grandfather backup performed?
A. daily
B. weekly
C. monthly
D. quarterly
A customer is using the GFS backup rotation plan with the weekly backups occuring Friday evening. The customer needs to restore a file that was known to be good on Friday morning. From which backup should the customer restore?
A. Father
B. Differential
C. Grandfather
D. Son
You have a disk enclosure with 14 x 72GB Wide-Ultra2 SCSI hard disks connected. You add an additional disk enclosure with 8 x 146GB Hot-Pluggable Ultra320 SCSI hard disks to an array controller. To optimize performance, you move 3 x
72GB Ultra2 hard disks to a new enclosure to balance the number of hard disks across two channels.
The disks in the new enclosure are not working correctly and the disks are not seen in the array controller management tool. There are no conflicting device IDs and termination is correct. All enclosures were powered on before powering up
the server. What are the possible causes of the problem? (Select two)
A. Ultra320 SCSI devices cannot be mixed with Wide-Ultra2 SCSI devices.
B. You must update the SCSI Controller BIOS to the latest supported revision.
C. The cables and/or connectors are faulty or not properly seated.
D. The number of disks exceeds the capability of the controller.
E. The SCSI I/O module on the disk enclosure is faulty.