You are attempting to connect a NetApp ONTAP cluster to a very complex network that requires LIFs to fail over across subnets. How would youaccomplish this task?
A. Configure an equal number of UFs on each subnet.
B. Configure VIP LIFs using OSPF.
C. Configure VIP LIFs using BGP.
D. Configure a I IF failover policy for each subnet inside a single broadcast domain.
You are troubleshooting a CIFS connection issue that is reported by some users. You decide to collect a packet trace.
In this scenario, after you generate the packet trace, where do you find the trace file?
A. /packet_traces of the node hosting the LIF
B. /etc/log/packet_traces of the node hosting the LIF
C. /etc/log/mlog/packet._traces Of all nodes
D. /vol0/paclcet_traces of the CIFS SVM
You have a customer who is concerned with high CPU and disk utilization on their SnapMirror destination system. They are worried about high CPU and disk usage without any user operations. In this situation, what should you tell the customer?
A. Suggest that the customer manually cancel any scanners on the destination to reduce CPU usage.
B. Explain that background tasks such as SnapMirror throttle up in the absence of user workload.
C. Suggest that the customer throttle their SnapMirror relationships to reduce resource consumption.
D. Explain that only user workload should use the CPU and Investigate further.
Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS(DDNS) capability available in NetApp ONTAP to easily advertise both data UFs to their clients. Currently. DNS is only responding with one data LIF. DDNS is enabled on the domain controllers.
Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose two.)
A. Disable the -vserver-fqdn parameter for the SVM DDNS services.
B. Remove the NFS protocol from the cifs_01 data LIF.
C. Enable the -use-secure parameter for the SVM DDNS services.
D. Enable the -is-enabledparameter for the SVM DDNS services
Your customer installed the shelf firmware for their NS224 shelf over a week ago, and the firmware has notupgraded on shelf 1 module B. The customer wants to know what the next steps would be to get the firmware upgraded after verifying that the shelf firmware is indeed loaded onto the system.
Which step would you perform to complete the firmware upgrade?
A. Reseat the NSM100 module.
B. Reseat the disk in Bay 0.
C. Power cycle the shelf.
D. Reseat the PSU of the shelf.
After expanding a two-node AFF A300 cluster with two AFF A700 nodes, you observe latencies when data is accessed indirectly. The system node run -node -command netstat command shows retransmits and packet drops on the LIFs. The AFF A700 nodes with 40 Gbps and the AFF A300 connect with 10 Gbps to the cluster interconnect. You are using Cisco Nexus 3132Q cluster interconnect switches. You just updated to ONTAP 9.8 software.
In this scenario, what is causing this problem?
A. The 10 Gbps to 10 Gbps cluster Interconnect is creating a speed mismatch.
B. AFF A300 and AFF A700 node mixing Isnot supported in ONTAP 9.8 software.
C. The AFF A300 Is using an adapter card for the cluster Interconnect, but only onboard ports are supported.
D. There is an NXOS firmware mismatch, verify in the Interoperability Matrix (1MTJ for a supportedversion.
A user reports that a colleague saved a file called Test.txt from a UNIX system to a multiprotocol volume. When opening the file later from a Windows system, it was not the file that they wanted. The file that they wanted was named TEST~1.TXT.
Which statement explains this behavior?
A. UNIX name mapping updated the filename.
B. A Snapshot copy preserved two versions of the file.
C. Windows Volume Shadow Copy Service stored an older version of the file.
D. Case Insensitivity of SMB clients caused the file to be displayed with a different name.
You Just used the CLI to create a NetApp ONTAP FlexGroup Volume on a NetApp Cloud Volumes ONTAP instance. After creation, you notice odd behavior in NetApp Cloud Manager. In this scenario,what Is the reason for this behavior?
A. Cloud Volumes ONTAP does not support FlexGroup volumes.
B. The Capacity Management Mode within Cloud Manager should be set to Manual.
C. The Capacity Management Mode within Cloud Manager should be set to Automatic.
D. Cloud Manager must be used to provision the FlexGroup volume.
When an administrator tries to create a share for an existing volume named voll, the process fails with an error.
Referring to the exhibit, what Is the reason for the error?
A. The volume must have a type of DP.
B. The volume has not beenmounted.
C. The CIFS service is not authenticating properly with the domain controller.
D. The CIFS service is not in workgroup mode.
You recently discovered the error message shown below in your ONTAP logs.
What should be your first action to correct this Issue?
A. Power cycle all the disk storage shelves that contain drives of the aggregate with the my_data_vol volume.
B. Determine the root cause behind the inconsistency before attempting any recovery procedure.
C. Use the storage takeover command on the storage controller that contains my_data_vol.
D. Use the wafliron command against my_data_vol to solve the inconsistency on the volume.