A technician is installing a server with sixteen 1 TB drives. They want the benefit of both speed and redundancy. Which of the following RAID configurations should be used?
A. RAID 0
B. RAID 1
C. RAID 3
D. RAID 50
An administrator has replaced a faulty drive in a server using software RAID. The drive needs to now be partitioned before being added back to the array. Which of the following tools should the administrator use to accomplish this?
A. chkdsk
B. mount
C. fsck
D. diskpart
An administrator is adding memory to a server. Once the system boots up, the same amount of memory appears as before the upgrade. Which of the following is the MOST likely cause?
A. The memory is not the correct CAS latency.
B. The memory is not installed in the correct slot.
C. The memory does not have the correct timing.
D. The memory is not the correct speed.
Due to slow backup response, an administrator installed a new driver for the SCSI card. After a server reboot the device is not working properly. Which of the following is the BEST course of action?
A. Reboot the server and restore files using ASR.
B. In Device Manager, locate the device, and click Roll Back Driver at the driver tab.
C. Restore the driver from the previous backup tape.
D. Go to Device Manager, locate the device, and click Restore Previous Driver at the driver tab.
Which of the following describes how many VRM's would be required in a system with quad Xeon CPU's?
A. 1
B. 2
C. 3
D. 4
Which of the following RAID levels would be appropriate given two drives and a need for fault tolerance?
A. RAID 0
B. RAID 1
C. RAID 5
D. RAID 10
Which of the following is the purpose of using a network attached storage device?
A. To provide storage space to network devices
B. To provide a high-speed network for different types of storage devices
C. To automatically load optical media via a robotic device
D. To classify, catalog, and maintain backup media
Which of the following provides the MOST redundancy for a corporate server network?
A. Server-to-server replication
B. Server clustering
C. Hot site
D. Disk-to-disk replication
A technician is working in a large corporate environment and is preparing to install patches on a mission critical server. Which of the following should the technician do FIRST before installing patches on the server?
A. Clone the server
B. Take a snapshot of the server
C. Backup the server
D. Deploy patches on a development server
Which of the following storage connectors connects only one drive on a cable?
A. Floppy
B. SATA
C. IDE
D. SCSI